Israeli Legislation.com
RegulationsHealthLabor Law

Work Safety (Construction Works) Regulations, 5748-1988

תקנות הבטיחות בעבודה (עבודות בניה), תשמ"ח-1988

Published: 1988-02-04Consolidated Hebrew text as of 2026-10-16 · Last amended 2020-05-21
Premium
Unofficial English translation — for reference only. It may contain errors or omissions and cannot be relied on as a legal text. Only the Hebrew text published in Reshumot is legally binding.More

This English text was translated from the official Hebrew using a range of translation tools, and it undergoes ongoing checks and updates. It is not a certified translation.

Despite these checks, it may contain errors, omissions, or imprecise renderings of legal terminology and cross-references, and it may not yet reflect the latest amendments. It cannot be relied upon as a legal text.

The Hebrew text as published in Reshumot (ספר החוקים) and on the Knesset website is the sole authoritative and legally binding version. In any discrepancy, the Hebrew text prevails.

This translation is provided for informational purposes only and does not constitute legal advice. For use in legal proceedings, request a certified Expert Legal Opinion.

Section C: Mechanised Scaffolding

Mechanised scaffolding§
45.
(a)A construction contractor shall not use mechanised scaffolding unless there is an engineering plan in respect thereof, and shall not install, dismantle or modify mechanised scaffolding, including its transfer from one structure to another within the site, except in accordance with such an engineering plan.
(b)A site manager shall supervise that the process of erecting mechanised scaffolding complies with sub-regulation (a), and shall stop work on mechanised scaffolding that does not comply with the conditions of that sub-regulation for as long as the use, erection, installation, transfer or modification is not in accordance with the engineering plan.
46.§

(Repealed — תשפ״ו)

47.§

(Repealed — תשפ״ו)

48.§

(Repealed — תשפ״ו)

49.§

(Repealed — תשפ״ו)

Inspection of mechanised scaffolding§
50.
(a)The construction contractor is responsible for ensuring that mechanised scaffolding is thoroughly inspected by an authorised inspector within the meaning of sections 76 and 81 of the Ordinance, in each of the following:
(1)immediately after its installation at the site and before the commencement of its use;
(2)immediately after every repair to the lifting or suspension system and before it is put back into operation;
(3)at least once every six months after the date of the last inspection, for as long as it is installed at the site;
(4)upon the transfer of mechanised scaffolding within the construction site.
(b)Mechanised scaffolding shall not be used unless it has been thoroughly inspected as stated in sub-regulation (a).
Report on the inspection§
51.
(a)An authorised inspector who has carried out an inspection of mechanised scaffolding as stated in regulation 50 shall deliver to the construction contractor, within two working days of the inspection, a report on the results of the inspection and shall send a copy thereof to the regional labour inspector.
(b)The report shall be drawn up on a form prescribed by the Chief Labour Inspector for this type of inspection, all the particulars indicated on the form shall be recorded therein, and it shall be signed by the person who carried out the inspection.
(c)The authorised inspector shall record in the general register that the inspection was carried out as stated in regulation 50.
(d)If a defect is discovered in the inspection by reason of which, in the opinion of the authorised inspector, the mechanised scaffolding is unfit for use, the authorised inspector shall record this in the general register and shall also notify, immediately, in writing, the construction contractor, the contractor's representative at the site where the scaffolding is installed and the regional labour inspector.
(e)The report referred to in sub-regulation (a) shall be appended to the general register at the site where the scaffolding is installed.
Prohibition of Use following Discovery of a Defect§
52.
(a)Where a defect is discovered in the course of an inspection as referred to in regulation 50 in mechanised scaffolding, by reason of which it is unfit for use, and notification thereof has been received as referred to in regulation 51(d), the scaffolding shall not be operated until it has been repaired.
(b)Where the defect has been repaired as referred to in sub-regulation (a), this shall be recorded in the general register.
(c)The site work manager and the construction operator are responsible for the implementation of the provisions of this regulation.
53.§

(Repealed — תשפ״ו)

Section D: Independent Scaffolding

Independent Scaffolding§
54.
(a)The founding of independent scaffolding and the manner of its erection shall be carried out as required by regulations 21 and 35.
(b)The stability and resistance of independent scaffolding shall be ensured by means of vertical ties, horizontal ties and diagonal ties installed throughout its height and conforming to the general requirements relating to scaffolding.
(c)The scaffolding shall be secured to the foundation to the extent necessary to ensure its equilibrium and stability.
(d)The height of the scaffolding shall not exceed three times the smallest dimension of its base.
(e)The height of scaffolding situated in an enclosed location protected from the effects of wind or weather may exceed what is stated in sub-regulation (d) but shall not exceed four times the smallest dimension of its base.
(f)Access to the work platform shall be by means of suitable stairs or ladders installed in such a manner that the stability of the scaffolding, when they are in use, shall not be impaired.
Mobile Independent Scaffolding§
55.

Mobile independent scaffolding shall not be used unless, in addition to what is stated in regulation 54 –

(1)the surface on which the scaffolding stands is level, covered with concrete, asphalt or paving, or is properly compacted to prevent the sinking of the scaffolding's wheels, without hollows or voids that could endanger its stability;
(2)it has been secured, by means of a suitable device, against movement from its position, for as long as a person is on it.
Transfer of Mobile Independent Scaffolding§
56.

Mobile independent scaffolding shall not be moved from place to place while a person is on it; the relocation of the scaffolding shall be carried out by means of a device operated close to its base.

Motorised mobile independent scaffolding§
57.

In addition to the provisions of regulation 55, motorised mobile independent scaffolding shall not be used unless:

(1)it is equipped with a system parallel to the lifting system that ensures the stopping of the work platform in the event of a failure in the lifting system;
(2)the balance of the work platform is ensured at all stages of lifting and working;
(3)it is equipped with stabilisers that ensure its stability in every position;
(4)control of the raising and lowering is in the hands of the person on the work platform;
(5)the work platform is electrically insulated from the system lifting it.

Section E: Suspended Scaffolding

Suspended scaffolding§
58.

A construction contractor shall not erect, install, dismantle or modify suspended scaffolding, and shall not use it, except in accordance with an engineering plan and in accordance with Section A, Section C and this Section.

Outriggers of suspended scaffolding with a winch§
59.

Suspended scaffolding that is raised or lowered by means of a manual winch shall not be installed and shall not be used unless its outriggers –

(1)are installed horizontally and in a manner that ensures a distance of at least 10 centimetres between the work platform and the wall, if the work is performed while standing, and at least 30 centimetres if the work is performed while seated;
(2)the length and cross-section of the outriggers ensure the strength and stability of the scaffolding;
(3)are spaced from each other at a distance appropriate to the distance between the transverse supports of the scaffolding floor;
(4)are firmly connected to the building by means of anchor rings or similar means, or are firmly tied to suitable counterweights whose integrity shall be properly ensured; and bags of loose material or barrels containing liquids shall not be used for this purpose;
(5)are equipped with suitable stops at their outer ends.
Cables of suspended scaffolding with a manual winch§
60.
(a)The steel cables from which scaffolding raised or lowered by means of a manual winch is suspended shall –
(1)have an appropriate safety factor, having regard to the greatest load that may be placed on them, provided that the safety factor shall be at least 10;
(2)be long enough so that at least two wraps of the wire cable remain around the winch drums when the scaffolding floor is at the lowest level of the working height to which it can be lowered;
(3)be firmly connected to the scaffolding at its outriggers or transverse supports and also to the winch drum;
(4)be vertical in the section between the outriggers or transverse supports to which they are connected and the winch;
(5)(Repealed)
(b)Parallel to each suspension cable, a cable with a safety device shall be installed that shall ensure that in the event of a failure in the cable or in the suspension mechanism, the floor shall remain suspended on the safety cable.
Prevention of snagging of suspended scaffolding with a winch§
61.

Adequate measures shall be taken to prevent the scaffolding from snagging on or being caught by any part of the structure.

Floor of scaffolding with a manual winch§
62.

The floor of suspended scaffolding raised or lowered by means of a manual winch shall not exceed 4 metres in length and shall be at least 65 centimetres in width.

Outriggers of suspended scaffolding without a winch§
63.

Suspended scaffolding that is not raised or lowered by means of a winch (hereinafter – suspended scaffolding without a winch) shall not be installed and shall not be used unless –

(1)the length and cross-section of its outriggers ensure strength and stability;
(2)its outriggers are firmly anchored at their inner ends or firmly tied to suitable counterweights, in a manner that does not allow their accidental removal or displacement, and bags of loose material or barrels containing liquids shall not be used for this purpose.
Suspension means for suspended scaffolding without a winch§
64.

The cables, chains, rods or metal pipes of suspended scaffolding without a winch shall –

(1)have an appropriate safety factor, having regard to the greatest load that may be placed on them, provided that the safety factor shall be at least 10;
(2)be firmly connected to the outriggers and to the body of the scaffolding;
(3)be vertical in the section between the outriggers and the point of connection to the scaffolding.
Floor of suspended scaffolding without a winch§
65.
(a)The width of the floor of suspended scaffolding without a winch shall be at least 65 centimetres.
(b)Where work is carried out while seated, a distance of at least 30 centimetres shall be ensured between the scaffolding floor and the wall.

Section F: Other Scaffolding

66.§

(Repealed — תשפ״ו)

67.§

(Repealed — תשפ״ו)

68.§

(Repealed — תשפ״ו)

69.§

(Repealed — תשפ״ו)

Cantilevered scaffolding and bracket scaffolding§
69a.
(a)A construction contractor shall not erect, install, dismantle, transfer or modify cantilevered scaffolding or bracket scaffolding, and shall not use them, except in accordance with an engineering plan.
(b)A site manager shall supervise that the process of installing, dismantling, transferring or modifying cantilevered scaffolding or bracket scaffolding as stated in sub-regulation (a) conforms to the engineering plan, and if it does not conform – shall stop work on the said scaffolding and shall not resume it for as long as the processes do not conform to the engineering plan.
Trestle scaffolding§
70.
(a)The height of the floor of trestle scaffolding shall not exceed 2 metres above the surface on which it is placed.
(b)Trestle scaffolding shall not be placed on other scaffolding.
(c)Trestle scaffolding shall be placed on a firm base and shall not be placed on the ground unless the area has been cleared, levelled and compacted beforehand as required, and adequate measures have been taken to prevent its supports from sinking into the ground.
71.§

(Repealed — תשפ״ו)

Chapter IV: Ladders

Material for a ladder§

72.

A construction operator shall supply to the site, in the required quantity, ladders that are free from defect and made of material suitable for the purpose for which the ladder is intended or for which it is used.

Height of a ladder§

73.
(a)A ladder whose length exceeds 2 metres shall extend at least one metre above the highest point reached by the person using it.
(b)The provisions of sub-regulation (a) shall not apply if at the highest point reached by a person using the ladder there is a suitable handhold.

Positioning of a mobile ladder§

74.
(a)A mobile ladder shall be placed on a firm horizontal base, supported and leaned against a stable support equally on both stiles so that it does not shift accidentally from its position during use.
(b)A ladder shall not be positioned unless it is leaning, at both its upper and lower resting points, on both its stiles at two stable points situated at the same level; a ladder shall not be leaned against one of its rungs.
(c)If it is not possible to position a ladder as provided in sub-regulation (a), a person shall stand at the base of the ladder and hold it so as to prevent it from shifting from the position.
(d)A mobile ladder, other than a mobile double-sided ladder, shall be positioned at a gradient of 1 horizontal to 4 vertical, and adequate measures shall be taken to prevent it from overturning or slipping during use.

Ladder as a means of passage between floors§

75.
(a)Where a ladder serves as a means of passage between two floors or between two levels of work platforms, the opening through which the ladder passes shall be as small as possible and shall be fenced on three sides.
(b)A ladder shall not be used as a means of passage between more than two floors or two levels of work platforms.

Reinforcement of a wooden ladder§

76.

A wooden ladder whose length exceeds 2 metres shall be reinforced by tie bolts at intervals of at least every 1.5 metres, or by rear wooden reinforcements at the said intervals.

Ladder Stiles§

77.
(a)A stile of a wooden ladder shall have a cross-sectional area of not less than 45 square centimetres, and its smallest dimension shall not be less than 4.5 centimetres.
(b)The grain of the wooden stiles shall be as straight as possible and its direction shall be approximately parallel to the length of the stile.

Ladder Rungs§

78.
(a)The rungs of a wooden ladder shall be of adequate strength, properly set within the stiles or supported by wooden cleats firmly attached to the stiles from rung to rung.
(b)No rung shall be missing from a ladder; no rung of a ladder shall be defective; the spacing between rungs shall be uniform, shall not be less than 30 centimetres and shall not exceed 35 centimetres; and no rung of a ladder shall be attached to a stile solely by nails or similar means of attachment.

Chapter V: Openings

Fencing of openings§

79.

Around an opening in a floor, working surface, passageway, scaffolding floor, roof, stairway run or lift shaft, one of the following shall be installed:

(1)suitable handrails and midrails of adequate strength to prevent a person from falling, as well as toeboards to prevent materials or equipment from falling, as stated in regulations 9 and 11;
(2)a cover of suitable strength to prevent a person, materials or equipment from falling, which shall be secured against accidental displacement from its position and shall not constitute an obstruction.

Fencing of a void in a wall§

80.

A void in a wall whose lower edge is less than 90 centimetres above the floor, working surface or passageway adjacent to it or through which a person is liable to fall to a depth exceeding 2 metres shall be fenced with suitable handrails and a midrail of adequate strength, as stated in regulations 9 and 11.

Maintenance of Fencing§

81.

Handrails, midrails, toeboards or covers that are required under the provisions of this Chapter shall not be removed from their position except to permit the transfer of material or equipment, and only for the period of time required for that operation, while taking the measures necessary to prevent a person or materials from falling.

Chapter VI: Formwork

Structure and maintenance§

82.

A formwork system shall be installed in a manner appropriate to its intended purpose and in a manner that prevents its collapse or the fall of a person or object from it, and shall conform to Israeli Standard SI 904 (hereinafter in this Chapter – the Standard) and also to an engineering plan – if one is required under regulation 85.

Materials for formwork§

83.

A construction contractor shall not install a formwork system except from materials that are suitable in terms of their quality and quantity and that have no visible defects, and also in accordance with an engineering plan – if one is required under regulation 85.

Inspection before casting§

84.
(a)If an engineering plan is required under regulation 85, the construction contractor shall not cast in formwork except after the site manager has inspected the formwork system in all its parts and has confirmed that the formwork is stable and suitable for its purpose and that the requirements set out in the engineering plan are met in respect thereof.
(b)The site manager shall record in the general register the results of the inspection as stated in sub-regulation (a) and shall deliver to the construction contractor the confirmation referred to in sub-regulation (a).

Design of formwork§

85.
(a)Where one of the following applies, the construction contractor shall not erect, dismantle or modify a formwork system unless the contractor holds an engineering plan:
(1)the Standard requires erection in accordance with a design;
(2)an existing component of the structure serves as a wall of the formwork;
(3)the formwork is of a type of special formwork to which SI 904 does not apply, such as vertically or horizontally sliding formwork.
(b)A construction contractor shall not erect, dismantle or modify a formwork system under this regulation except under the supervision of the site manager.
86.§

(Repealed — תשפ״ו)

The Foundation for Supports§

87.
(a)Supports shall be placed on a foundation in which all of the following conditions are met:
(1)its surface is clean, strong, stable, level and drained, and there are no depressions or voids in it or in its immediate vicinity that could endanger the stability of the formwork system;
(2)fill soil serving as the foundation has been properly compacted;
(3)if the supports are not intended to be vertical or the surface on which they rest is not horizontal, appropriate measures have been taken to ensure the stability of the supports and the formwork system.
(b)Supports shall not be placed on blocks, bricks or layered wooden boards.

Manner of positioning supports§

88.
(a)(Repealed)
(b)(Repealed)
(c)Metal supports shall be positioned in a single layer only; a support shall not be placed on top of another support.
89.§

(Repealed — תשפ״ו)

90.§

(Repealed — תשפ״ו)

91.§

(Repealed — תשפ״ו)

92.§

(Repealed — תשפ״ו)

93.§

(Repealed — תשפ״ו)

94.§

(Repealed — תשפ״ו)

95.§

(Repealed — תשפ״ו)

96.§

(Repealed — תשפ״ו)

97.§

(Repealed — תשפ״ו)

98.§

(Repealed — תשפ״ו)

99.§

(Repealed — תשפ״ו)

99a.§

(Repealed — תשפ״ו)