Business Licensing (Petroleum Storage) Regulations, 5737-1976
תקנות רישוי עסקים (אחסנת נפט), תשל"ז-1976
Unofficial English translation — for reference only. It may contain errors or omissions and cannot be relied on as a legal text. Only the Hebrew text published in Reshumot is legally binding.More
This English text was translated from the official Hebrew using a range of translation tools, and it undergoes ongoing checks and updates. It is not a certified translation.
Despite these checks, it may contain errors, omissions, or imprecise renderings of legal terminology and cross-references, and it may not yet reflect the latest amendments. It cannot be relied upon as a legal text.
The Hebrew text as published in Reshumot (ספר החוקים) and on the Knesset website is the sole authoritative and legally binding version. In any discrepancy, the Hebrew text prevails.
This translation is provided for informational purposes only and does not constitute legal advice. For use in legal proceedings, request a certified Expert Legal Opinion.
By virtue of my authority under Sections 173 and 216 of the Work Safety Ordinance [New Version], 5730-1970 (hereinafter – the Ordinance), and Section 11a of the Business Licensing Law, 5728-1968 (hereinafter – the Law), I hereby make these Regulations:
Chapter I: General
Definitions§
In these Regulations –
"naked flame" – a flame, spark, electrical spark or any source having sufficient energy to cause the ignition of gases or liquids stored in an installation;
"installation owner" – any of the following:
"bund" – an area on which a tank or tanks for petroleum are constructed, surrounded by walls suitable for preventing the spread of liquid beyond it;
"fence" – a built wall or strong metal mesh fence at least 2.5 metres in height with at least two gates spaced as far apart from each other as possible;
"close-mesh fence" – a fence not less than 1.8 metres in height, the lower part of which, to a height of at least 0.6 metres, is made of opaque and non-combustible material and the upper part of which is made of close mesh or opaque and non-combustible material;
"LPG" – liquefied petroleum gas;
"bund wall" – the wall surrounding the area on which a tank or tanks for petroleum are constructed, built in accordance with the requirements of these Regulations;
"licensing authority" – as defined in the Law;
"tank farm" – a site for the storage of liquid petroleum in quantities exceeding 150 cubic metres (hereinafter – cu.m.), including a terminal;
"LPG tank farm" – a site at which LPG is stored in a quantity exceeding 10 kilolitres in stationary tanks for a commercial purpose;
"dispenser" – a device used for dispensing petroleum from a storage tank, whether the pump is installed in the dispenser or within the tank;
"central supply depot" – an installation intended for the central supply of LPG at medium pressure to residential buildings, craft buildings, industry and for agricultural purposes;
"LPG warehouse" – a site at which LPG is stored for commercial purposes in tanks and cylinders to which Israeli Standard SI 70 (tanks for liquefied petroleum gases) (commercial petroleum gases) applies, as well as any depot for the central supply of LPG;
"private warehouse" – a site at which liquid petroleum is stored and used for the needs of a factory as defined in the Ordinance, in a quantity approved by the Chief Labour Inspector for the factory or for a category of factories;
"wholesale warehouse" – a site at which Class C petroleum is stored in a quantity not exceeding 50 cu.m. for the purpose of sale to retailers by tankers;
"tanker" – a motor vehicle for the transport of petroleum products;
"tank" – an LPG tank or a petroleum tank, as the case may be;
"LPG tank" – a receptacle for LPG conforming to Israeli Standard SI 158 Part 1 – Installations for Liquefied Petroleum Gases (LPG): Storage Vessels, or constructed in accordance with an accepted construction method approved by the Chief Labour Inspector;
"petroleum tank" – a receptacle for liquid petroleum conforming to one of the Israeli Standards SI 4468 Parts 1 and 2, welded steel fuel tanks, or SI 4571 Part 1, double-wall underground fuel tanks: manufacture and cathodic protection, as the case may be, or another standard approved by the Chief Labour Inspector;
"labour inspector", "regional labour inspector" and "Chief Labour Inspector" – as defined in the Organisation of Labour Inspection Law, 5714-1954;
"installation" – a tank farm, an LPG tank farm, a public filling station, an LPG warehouse, an internal filling station, a private warehouse and a wholesale warehouse;
"petroleum" – any flammable liquid or hydrocarbon gas, including LPG, natural gas and any other flammable substance declared by the Minister of Labour to be petroleum for the purposes of these Regulations, excluding lubricating greases, lubricating oils and asphalt;
"liquid petroleum" – petroleum, excluding LPG and natural gas;
"Class A petroleum" –
"Class B petroleum" – petroleum whose flash point exceeds 20 degrees Celsius in the test referred to in the definition of Class A petroleum, but does not exceed 55 degrees Celsius in the Pensky Martens Closed Tester Method ASTM D 93–66;
"Class C petroleum" – petroleum whose flash point exceeds 55 degrees Celsius in the test referred to in the definition of "Class B petroleum";
"hazard point" – any of the following:
"tank opening" – any opening or connection to a tank through which vapours may escape into the open air, such as a ventilation pipe, a tank fuel-filling pipe and a measuring opening;
"close mesh" – mesh made of galvanised iron or non-corroding metal, in which the wire thickness is at least 0.6 mm and the size of the spaces does not exceed 12×12 mm;
"internal filling station" – a site for storing petroleum for fuelling vehicles for self-consumption in a quantity not exceeding 100 cu.m.;
"public filling station" – a site for storing petroleum for sale to the public for the purpose of fuelling vehicles or for other purposes, including an internal filling station in which the quantity of petroleum stored exceeds 100 cu.m.
Application§
Obligation to Obtain a Licence§
Licence Application§
The installation owner shall submit an application for a licence to the licensing authority in accordance with the provisions of the Business Licensing (General Provisions) Regulations, 5761-2000; the plans to be attached shall also clearly specify all particulars of the installation, including the capacity of the petroleum tanks by type, as well as details of high-voltage and extra-high-voltage power lines and electrical installations located within a distance of up to 35 metres from the installation.
(Repealed — תשס״ה)
Cleanliness of the Installation§
Every installation shall be maintained in a clean condition, including free of weeds.
Storage of Objects§
No person shall store or permit the storage of objects and goods in an installation except in accordance with the conditions of the licence.
Portable Receptacles§
Portable receptacles containing petroleum shall not be stacked one on top of the other to a height liable to endanger their strength or the stability of the stack; LPG cylinders shall be stored upright, whether full or empty, except for cylinders without a safety valve, which shall be stored horizontally or upright.
Ventilation of Buildings§
Buildings for storing portable receptacles containing petroleum shall be constructed of non-combustible material, ventilated by through-ventilation openings covered with close mesh, near the floor and near the ceiling.
Fire Prevention and Fire-Fighting Equipment§
Appointment of a Responsible Person§
In a tank farm and in an LPG tank farm, a person responsible for their operation shall be appointed; that person's name and address as well as the telephone number at which they can be reached shall be indicated on a sign posted in a visible place.
Entry into Tanks§
No person shall enter or permit another to enter a tank except after all necessary safety measures have been taken and after obtaining written approval from the installation owner or a person authorised for that purpose.
Earthing§
In a tank farm and in an LPG tank farm –
Distances from Power Lines§
Deviations from Distances§
The Chief Inspector may prescribe deviations from the distances set out in regulation 13a and under conditions to be prescribed in each individual case, if the distance from tank openings or from a dispenser to electricity poles justifies this in his opinion; if the distance between electricity poles is less than customary, if protection exists beneath the wires preventing their contact with installations or the ground, or if the installation is in an urban area.
Shelters§
A person constructing a shelter shall ensure that petroleum and petroleum vapours do not accumulate in it.
Chapter II: Tank Farms
Permitted Quantities§
No person shall store or permit the storage of petroleum in a tank farm in a quantity exceeding that approved by the regional inspector or otherwise than in accordance with the conditions and restrictions he has prescribed.
Fencing§
A tank farm shall be enclosed by a fence.
Prohibitions and Signage in a Tank Farm§
In a tank farm –
(Repealed — תשס״ה)
Prohibition on Bringing in Matches and Lighters§
No person shall bring matches or lighters into a tank farm except with the consent of the person responsible for its operation.
Storage of Class A Petroleum§
Class A petroleum shall be stored in floating-roof tanks, or in tanks with special suitable arrangements approved in advance by the Chief Inspector.
Distances between above-ground tanks§
The distance between the walls of two adjacent above-ground tanks shall be as follows:
Distances between tanks and fence§
The distance between the wall of an above-ground tank and the fence of a tank farm shall be as follows:
Bund§
Bund drainage§
Roads for fire-fighting vehicles§
A tank farm shall be equipped along its inner fences with a road for the passage of fire-fighting vehicles, as well as other access and transit roads, which –
Deviations from distances and capacity§
The Chief Inspector may approve distances smaller than those prescribed in regulations 20 and 21, and may permit a deviation from the capacity referred to in regulation 22(f) and from the provision of regulation 23(b), if, after consultation with the fire authority on all matters relating to fire prevention and fire-fighting, the circumstances justify it in his opinion.
Read the entire law on one page — continuous text, no page breaks, plus formal citations.
Made under these laws
Other regulations under the Work Safety Ordinance [New Version]
- Work Safety (Construction Works) Regulations, 5748-1988
- Work Safety (Crane Operators, Operators of Other Lifting Machines and Signallers) Regulations, 5753-1992
- Work Safety (Direct-Action Nail-Driving Devices) Regulations, 5744-1984
- Work Safety (First Aid in Workplaces) Regulations, 5748-1988
- Work Safety (Hydrostatic Pressure Testing of a Pressure Installation) Regulations, 5756-1995
- Work Safety (Installation of a Door in a Lift Car) Regulations, 5753-1993
תקנות רישוי עסקים (אחסנת נפט), תשל"ז-1976
petroleum storage regulations
business licensing petroleum storage
takkanot rishuuy eskakim achsanat neft
oil storage licensing
petroleum storage licensing 1976
achsanat neft regulations
oil storage business licence
petroleum storage rules 5737
fuel storage licensing israel