Israeli Legislation.com

Business Licensing (Adequate Sanitary Conditions for Eating Establishments) Regulations, 5743-1983

תקנות רישוי עסקים (תנאי תברואה נאותים לבתי אוכל), תשמ"ג-1983

Published: 1983-09-06Consolidated Hebrew text as of 2026-08-30 · Last amended 2020-05-21
Premium
Unofficial English translation — for reference only. It may contain errors or omissions and cannot be relied on as a legal text. Only the Hebrew text published in Reshumot is legally binding.More

This English text was translated from the official Hebrew using a range of translation tools, and it undergoes ongoing checks and updates. It is not a certified translation.

Despite these checks, it may contain errors, omissions, or imprecise renderings of legal terminology and cross-references, and it may not yet reflect the latest amendments. It cannot be relied upon as a legal text.

The Hebrew text as published in Reshumot (ספר החוקים) and on the Knesset website is the sole authoritative and legally binding version. In any discrepancy, the Hebrew text prevails.

This translation is provided for informational purposes only and does not constitute legal advice. For use in legal proceedings, request a certified Expert Legal Opinion.

By virtue of my authority under section 10 of the Business Licensing Law, 5728-1968 (hereinafter – the Law), and by virtue of the authority under section 3 of the Public Health Ordinance (Food), 1935, which I have assumed pursuant to section 32 of Basic Law: The Government, I hereby make these Regulations:

Chapter I: Interpretation

Definitions§

1.

In these Regulations –

"eating establishment" – any business of the businesses listed in items 4.2 and 7.9 of the Schedule to the Order;

"Instructions for Sanitary Installations" – the Instructions for Sanitary Installations (Horaot le-Mitkane Tibrua), 5730-1970, as defined in regulation 1 of the Planning and Building Regulations (Application for Permit, Conditions and Fees), 5730-1970 (hereinafter – the Planning and Building Regulations), a copy of which has been deposited at every district and sub-district health office;

"durable material" – a material in which all of the following conditions are met:

(1)it is rigid, smooth and non-absorbent;
(2)it does not change its physical, chemical or biological properties as a result of its use, cleaning or disinfection, including by way of the formation of cracks, air pockets, rust, disintegration, emission of substances and the like;

and including – blocks, concrete, cement board, porcelain, ceramics and stainless steel;

"food" – anything intended for human consumption by eating, drinking or chewing, including raw materials for the preparation of food, but excluding a living animal and a substance used solely in medicine;

"raw food" – food that has not yet been prepared for consumption;

"pests" – insects, rodents, birds and other animals;

"kitchen" – a room designated for the preparation of food or beverages, the washing of utensils, or the keeping of prepared food;

"the Director" – the Director General of the Ministry of Health or a person authorised by him for the purposes of these Regulations or any part thereof;

"cleaning" – an act of removing all contamination that is visible to the eye, detectable by touch or detectable by smell;

"refrigeration installation" – an electric refrigerator, cold room, deep-freeze installation or deep-freeze room.

"the Order" – the Business Licensing Order (Businesses Requiring a Licence), 5773-2013.

Chapter II: Licensing

Conditions for Licensing§

2.
(a)No licence for an eating establishment shall be granted to a person, and no person shall operate an eating establishment, unless that person complies with the provisions of these Regulations and the conditions set out in the Schedule under the section corresponding to the type of eating establishment, as specified in the table below, are met in the eating establishment, all to the satisfaction of the Director.
(b)The Director may require the owner of an eating establishment, or its manager, to demonstrate familiarity with these Regulations as a condition for the approval of the application for a licence.
Conditions for Licensing
Column A – Name of Business in the ScheduleColumn B – Business No. in the OrderColumn C – Name of Business in the OrderColumn D – Section in the Schedule
Restaurant4.2aA restaurant, including food delivery and including the serving of intoxicating beverages for consumption on the premises, and which is not a business whose principal activity is the serving of intoxicating beverages for consumption at the place of serving as referred to in item 4.8 of the OrderSection C
Snack bar4.2bA café, snack bar, or other eating establishment, including food delivery and including the serving of intoxicating beverages for consumption on the premises, and which is not a business whose principal activity is the serving of intoxicating beverages for consumption at the place of serving as referred to in item 4.8 of the OrderSection A
Café4.2bSection B
Pizzeria4.2bSection D
Börek snack bar4.2bSection E
Falafel snack bar4.2bSection F
Preparation of food for sale for consumption away from the place of preparation4.2cPreparation of food for sale for consumption away from the place of preparation, including food delivery and excluding catering as defined in item 4.6e of the Order—
Banquet hall7.9A hall or garden for celebrations and events, whose principal activity is the holding of events, including the serving of intoxicating beverages for consumption at the place of servingSection H

Exemption from Certain Conditions§

2a.

Where an eating establishment serves a limited population or carries out food preparation activities on a limited scale, the Director may, notwithstanding the provisions of these Regulations, exempt it, upon application by its owner, from the provisions of sections 6, 9, 27 and 31 of the Schedule, as the case may be, and also from the provisions of sections 2, 5, 8, 11, 16, 21 or 30 of the Schedule, insofar as they relate to the combined floor area of the dining room and the service rooms, all subject to such conditions as shall be specified in the licence.

Attachment of Appendices to Licence Application§

3.
(a)An application for a licence for an eating establishment shall be accompanied by a site plan and drawings that were attached to the application for a building permit under the Planning and Building Regulations, on which the following particulars shall be indicated:
(1)the orientation and cross-section of the eating establishment;
(2)the width, length, height and designated use of each room in the eating establishment;
(3)if ventilation is mechanical – the installations and their capacities;
(4)(Repealed)
(5)marking of all fixed sanitary fixtures, fittings, water supply pipes and sewage pipes, with an indication of their diameter, gradient and method of sewage disposal;
(6)marking of refuse storage installations;
(7)the arrangement of equipment and furniture within the rooms of the eating establishment.
(b)The marking for the purposes of sub-regulation (a) shall be in accordance with the drawings and the example on pages 115 and 1111 of the SISA.
(c)The scale of the engineering drawings shall be 1:100, and the Director may require the applicant to submit an orientation drawing at a scale of 1:50.
(d)The site plan shall indicate the following particulars:
(1)a neighbourhood plan at a scale of 1:2,500;
(2)a plot plan at a scale of 1:250.

Renewal of Licence§

4.
(a)The provisions of regulation 3 shall also apply to an application for the renewal of a licence, unless the following conditions are met –
(1)since the last approval of the business licence, no changes have occurred in the particulars submitted under regulation 3 and the orientation and cross-section drawings reflect the existing situation;
(2)a written declaration, signed by the applicant, has been attached to the application, stating that the appendices submitted under regulation 3 in connection with a previous application reflect the existing situation at the time of submission of the application for renewal of the licence.
(b)Prior to the expansion of an eating establishment, or prior to making any alterations therein that would affect the engineering drawings, the appendices referred to in regulation 3(a) shall be submitted to the Director for approval, as the case may be.

Chapter III: Buildings

Types of Rooms§

5.

Every eating establishment shall have a kitchen, a dining room, a service room and a storeroom.

6.§

(Repealed — תשפ״ו)

Mezzanine§

7.

In an eating establishment, except above the kitchen, a mezzanine may be built or may exist, provided it meets the conditions specified in the Planning and Building Regulations.

Walls, Partitions and Ceilings§

8.
(a)The walls, partitions and ceilings of the buildings of the eating establishment and of the service rooms shall –
(1)be constructed of durable material or of concrete, bricks, cement blocks or any other hard building material that is not wood, metal or asbestos;
(2)be smooth on their interior surface;
(3)be sealed against the penetration or nesting of pests, and against the penetration of moisture;
(4)be clean and intact.
(b)If a decorative ceiling is installed in an eating establishment, the following provisions shall also apply to it, as the case may be:
(1)if the decorative ceiling is installed in the dining room, it shall be constructed of material as referred to in sub-regulation (a)(1) or made of material approved in advance by the Director;
(2)if the decorative ceiling is installed in the kitchen, it shall not be of the demountable ceiling type.
9.§

(Repealed — תשפ״ו)

Floor§

10.
(a)The floor of the eating establishment shall be free of depressions and shall be paved with tiles or another material approved by the Director, or paved or covered with durable material.
(b)The floor shall be in good repair and clean at all times.
(c)The floor shall be constructed with a gradient towards the floor trap, and where there is no such trap, a drainage channel shall be installed.

Drainage Channel and Waste-Water Trap§

11.
(a)The drainage channel, if any –
(1)shall be rounded and connected to the building's sewage system;
(2)there shall be a waste-water trap between it and the building's sewage system;
(3)there shall be no blockages of liquids or accumulations of any waste therein;
(4)shall be made of a smooth-finished material.
(b)The floor trap shall conform to the requirements of the SISA in this regard.

Doors and Windows§

12.
(a)Doors and windows of the eating establishment –
(1)shall be clean, intact and in good repair;
(2)(Repealed)
(3)wooden parts shall be painted with oil paint; doors or windows whose frames are made of stainless metal need not be painted.
(b)Doors and windows of the kitchen shall be fitted with a screen to prevent the entry of pests.

The Kitchen§

13.
(a)The kitchen shall be located within the building of the eating establishment and shall meet the following conditions –
(1)sinks and taps for the supply of hot and cold water shall be installed therein;
(2)a section for the washing of utensils shall be designated therein;
(2a)there shall be no exposed pipework visible to the eye therein, unless the pipework is drinking-water or fire-fighting pipework;
(3)(Repealed)
(4)the walls of the kitchen or any partition therein shall be covered with light-coloured porcelain tiles or another material approved by the Director, or with durable material capable of being cleaned, in a light colour or another colour on which dirt can be seen, to a height of at least 1.80 metres from the floor.
(b)Food shall not be sold to the public directly from the kitchen in any manner whatsoever.

The Storeroom and Food Storage§

14.
(a)The storeroom shall be adjacent to the kitchen or within a distance not exceeding 100 metres from it.
(b)Notwithstanding the provisions of sub-regulation (a), regulation 5 and sections 2(a), 5, 8(a), 11, 16, 21 and 30 of the Schedule with respect to the minimum area of a storeroom in an eating establishment, an eating establishment may have no storeroom, or may have a storeroom located outside the eating establishment or whose area is smaller than that prescribed in the Schedule, subject to the following conditions:
(1)if the eating establishment has a storeroom – the storeroom of the eating establishment shall not be at a distance exceeding 100 metres from the kitchen of the eating establishment;
(2)if the eating establishment has no storeroom, whether within the eating establishment or outside it, or if the eating establishment has a storeroom whose area is smaller than that prescribed in the Schedule – the eating establishment shall have refrigeration installations, closed drawers, closed cupboards or another closed installation, designated for the storage of food.
(c)If the storeroom is outside the eating establishment, at a distance exceeding 25 metres from the kitchen of the eating establishment, food shall be transported from the storeroom to the kitchen, and vice versa, in a manner that maintains the cold chain of the food and with separation between raw food and partially or fully processed food.

Protective Measures for Food§

15.
(a)Food shall not be placed on a counter unless adequate protective measures have been installed on it against the penetration of contamination and pests into the food.
(b)(Repealed)
(c)Roasting, grill, frying and baking oven installations shall be installed within the business at a distance of at least 2 metres from the entrance threshold.

Chapter IV: Equipment

Fixed Equipment§

16.

Fixed equipment shall be installed in such a manner that it can readily be cleaned from all its sides, provided that parts of equipment that are attached to walls, to the floor or to other equipment shall be installed in a manner that prevents the accumulation of dirt or the penetration of pests between them.

Movable Equipment§

17.

Movable equipment shall be installed in one of the following ways:

(1)in such a manner that it can readily be moved for cleaning purposes by means of wheels installed on it or by another method approved by the Director;
(2)the height of the underside of the equipment from the floor shall be at least 20 cm, or a lesser height that allows the floor beneath it to be cleaned.

Equipment Coming into Contact with Food§

18.
(a)Every part of equipment that comes into direct contact with food –
(1)shall not contain lead, copper, cadmium or any other substance that may be toxic to a person;
(2)shall not be made of wood;
(3)shall have a smooth surface made of a material that does not absorb liquids and does not flake;
(4)shall be easily dismantled for cleaning and disinfection purposes if it is composed of various parts;
(5)shall be intact, in good repair and clean.
(b)Shelves and surfaces intended for the keeping of food that is in containers shall be made of non-corroding material.
(c)The distance between the shelves and the wall shall be at least 5 cm, or a lesser distance that allows the wall to be ventilated.
(d)The distance between the lowest shelf and the floor shall be at least 40 cm, or a lesser distance that allows the shelves, walls and floor to be cleaned.

Equipment Not Coming into Contact with Food§

19.

Parts of equipment that do not come into direct contact with food shall be intact, in good repair and clean, and shall be constructed or coated with a material that does not absorb liquids.

Chapter V: Refrigeration

Indicator Thermometer§

20.

Cold rooms and refrigerators shall be equipped with an indicator thermometer.

Recording Thermometer in Cold Room§

21.

A cold room shall also be equipped with a recording thermometer in which the following conditions are met –

(1)its display panel shall be installed outside the cold room at a height of 1.60 to 1.70 metres from the floor, or at another height provided it is in a position visible to the eye;
(2)its accuracy range shall be ±0.5 degrees Celsius within the temperature range in which it operates.

Noise limitation§

22.

Refrigeration installations shall not cause noise exceeding that specified in regulation 2 of the Abatement of Nuisances (Unreasonable Noise) Regulations, 5750-1990 (hereinafter – the Unreasonable Noise Regulations).

Keeping raw food and prepared food in refrigeration installations§

23.

Raw food shall be kept in refrigeration installations separately from food prepared for eating; the separation shall be by means of partitions within the same refrigeration installation or by another means approved by the Director.

Refrigeration installation§

24.
(a)A refrigeration installation shall have air circulation in such a manner as to reach all food stored therein.
(b)The size of a refrigeration installation shall be appropriate to the scale of activity of the eating establishment.
25.§

(Repealed — תשפ״ו)

Chapter VI: Ventilation and Lighting

Ventilation and lighting§

26.

The structure of the eating establishment shall be ventilated by one of the following means –

(1)windows opening to the outside air (hereinafter – natural ventilation);
(2)a mechanical ventilation system (hereinafter – artificial ventilation).

Removal of odours, vapours and fumes§

27.
(a)Natural or artificial ventilation shall remove vapours, fumes and other undesirable odours from all premises of the eating establishment, to the satisfaction of the Director.
(b)The Director may require the installation of a hood containing a canopy and fan above every cooking, baking or roasting installation, or additional installations for the prevention of the dispersal of odours to the surroundings; where the Director has required the installation of a hood as aforesaid, the hood shall be installed in one of the following ways:
(1)the hood shall be connected to a chimney whose height is 2 metres above the structure in which the eating establishment is situated, or above the roof of the tallest building in the vicinity located within a distance of up to 50 metres from the eating establishment, whichever is higher;
(2)the hood shall be connected to an installation that prevents the emission of odours and vapours to the surroundings, or to another means that prevents the emission of odours, vapours and smoke to the surroundings.
(c)In an eating establishment situated in a residential area or in a residential and commercial area, coal may not be used for frying, grilling, roasting and baking.

Air replacement in rooms of the eating establishment§

28.

Artificial ventilation shall replace, within one hour, the air in the rooms of the eating establishment listed below in Column A not less than the number of times indicated alongside them in Column B:

Air replacement in rooms of the eating establishment
Column A – Rooms of the eating establishmentColumn B – Minimum number of air replacements per hour
Kitchen20
Food store6
Service rooms8
Dining rooms4

Installation of an artificial ventilation system§

29.
(a)Artificial ventilation shall be installed in accordance with the Israeli Standard and, in the absence of such a standard, in accordance with a standard approved by the Director, provided that it does not cause noise exceeding that specified in the Unreasonable Noise Regulations.
(b)Ventilation installations shall be constructed in such a manner that condensation water or oil does not drip from them.

Electric bulbs§

30.

Fixed lighting installations shall be present in all rooms of the eating establishment and in the storerooms.

Adequate lighting§

31.

The intensity of lighting in the rooms of the eating establishment listed below in Column A shall be not less than that indicated alongside them in Column B:

Adequate lighting
Column A – Rooms of the eating establishmentColumn B – Minimum lighting intensity in lux
Kitchen and work surfaces therein400
Storeroom300
Service rooms300
Corridors and stairwells200
Above dining tables for the public300

Protective means§

32.

In the kitchen and in the storeroom, electric bulbs shall be fitted with protective means, including built-in protective means, to prevent the falling of glass fragments into food.

Page 1 of 3

Read the entire law on one page — continuous text, no page breaks, plus formal citations.

RegulationsCorporate & Business

תקנות רישוי עסקים (תנאי תברואה נאותים לבתי אוכל), תשמ"ג-1983

Business Licensing Regulations 1983

Eating Establishments Sanitary Conditions

Takkanot Risui Iskaim Tverua

Restaurant Health Code Israel

Food Service Sanitation Regulations

Eating Establishments Health Standards

Business Licensing Sanitary Conditions

Restaurant Hygiene Requirements

Food Establishment Regulations 1983

Kashrut Sanitation Regulations