Israeli Legislation.com

Planning and Building Regulations (Implementation of Accessibility Adjustments for a New Educational Institution), 5779-2018

תקנות התכנון והבנייה (ביצוע התאמות נגישות למוסד חינוך חדש), תשע"ט-2018

Published: 2018-10-22Consolidated Hebrew text as of 2026-10-27 · Last amended 2024-06-26
Premium
Unofficial English translation — for reference only. It may contain errors or omissions and cannot be relied on as a legal text. Only the Hebrew text published in Reshumot is legally binding.More

This English text was translated from the official Hebrew using a range of translation tools, and it undergoes ongoing checks and updates. It is not a certified translation.

Despite these checks, it may contain errors, omissions, or imprecise renderings of legal terminology and cross-references, and it may not yet reflect the latest amendments. It cannot be relied upon as a legal text.

The Hebrew text as published in Reshumot (ספר החוקים) and on the Knesset website is the sole authoritative and legally binding version. In any discrepancy, the Hebrew text prevails.

This translation is provided for informational purposes only and does not constitute legal advice. For use in legal proceedings, request a certified Expert Legal Opinion.

Chapter VIII: Sanitary Installations

Number of Accessible Toilets in a New Educational Institution§

26.
(a)Every new educational institution shall have accessible toilets that shall be counted within the number of toilets required under the building regulations.
(b)In every building in a new educational institution in which a toilet is required under the building regulations, there shall be at least one accessible toilet serving both sexes, or there shall be two accessible toilets, one intended for women and the other for men; in the central building of a new educational institution there shall be at least two accessible toilets, one intended for women and the other for men, and there shall be at least one accessible toilet on each floor of the central building; at least one accessible toilet in the central building shall be of type 2.
(c)Notwithstanding the provisions of sub-regulation (b) –
(1)in a new educational institution serving women or men only, only one accessible toilet may be installed out of the total number of toilets required;
(2)in a kindergarten, only one accessible toilet may be installed in the building, serving both sexes.

Accessible Toilet§

27.

An accessible toilet shall comply with the requirements of Israeli Standard SI 1918 Part 3.1, type 1 or type 2, as the case may be.

Location of Accessible Toilet§

28.

The horizontal walking distance from the entrance door of every accessible learning space, in a building in which accessible toilets have been installed, to the entrance door of an accessible toilet, shall not exceed 75 metres.

Urinals§

29.

A urinal in a building in a new educational institution shall be a bowl urinal, and its installation shall be in accordance with the requirements of SI 1918 Part 3.1, in section 2.11.8 dealing with urinals.

Drinking Installations§

30.

Drinking installations in a building of a new educational institution shall comply with the provisions of item 8.224 of Section C of Chapter I of Part 8-A of the Second Schedule to the Permit Application Regulations.

Changing Room, Cubicle and Shower§

31.
(a)In a building or part of a building of a new educational institution in which there are changing rooms, changing cubicles or showers, the provisions of items 8.150 to 8.156 of Section J of Chapter I of Part 8-A of the Second Schedule to the Permit Application Regulations shall apply.
(b)Hooks in changing rooms, changing cubicles and showers as referred to in sub-regulation (a) shall be in visual contrast to the wall to which they are affixed.

Chapter IX: Places of Assembly

Special Seating Places in Places Intended for Assembly in a New Educational Institution§

32.

In a place intended for assembly that is tiered or has fixed seating in a new educational institution, there shall be special seating places complying with the provisions of item 8.210 of Section XIII of Chapter I of Part 8-A of the Second Schedule to the Permit Application Regulations; however, an accessible route to a lower surface in a tiered space may be by way of a courtyard, provided that the length of the accessible route does not exceed 30 metres and the route is covered, to the extent that the place intended for assembly is covered.

Chapter X: Acoustics

Installation of Acoustic Ceiling§

33.

In at least one third of all learning spaces in a new educational institution and also in designated classrooms, accessibility adjustments shall be implemented in accordance with the provisions of SI 2004 Part 1 Acoustics in Non-Residential Buildings: Learning Spaces in Permanent Structures – Criteria, Design Requirements and Guidelines.

Chapter X-A: Special Storage Units in a Boarding School

Special Storage Units in a New Educational Institution that is a Boarding School§

34.
(a)In a new educational institution that is a boarding school, one special storage unit shall be installed for every 12 storage units, and not less than one.
(b)The provisions of items 8.185 to 8.194 of Section XI of Chapter I of Part 8-A of the Second Schedule to the Permit Application Regulations shall also apply to a special storage unit.

Chapter XI: Additional Accessibility Adjustments

Signage§

35.
(a)A new educational institution shall have directional signs to which the provisions of SI 1918 Part 4 shall apply, in the following places:
(1)in the lobby of a building or at a main entrance, there shall be directional signs to a lift, to toilets and to management and secretariat rooms;
(2)adjacent to every vehicle entrance there shall be directional signs to an accessible parking place;
(3)at an accessible parking place there shall be signs in accordance with Israeli Standard SI 1918 Part 4, in section 2.1.3.1 dealing with accessible parking places.
(b)Identification signs shall comply with the provisions of SI 1918 Part 4, sections 2.1.4.2 and 2.1.6.2.

Operating Devices§

36.

Operating devices intended for public use shall comply with the provisions of SI 1918 Part 1, section 2.5.

Lighting§

37.

Lighting in an educational institution shall be planned in accordance with the provisions of Israeli Standard SI 8995: Lighting for Workplaces inside Buildings, and lighting in outdoor areas of an educational institution shall be planned in accordance with the principles of Israeli Standard 1918 Part 4, in section 2.8 dealing with lighting.

Chapter XII: Commencement and Transitional Provision

Commencement§

38.

These Regulations shall commence one year from the date of their publication (hereinafter – the commencement date).

Transitional Provision§

39.

Notwithstanding the provisions of these Regulations, a new educational institution or an addition to an existing educational institution in respect of which a decision on an application for a permit submitted for their construction or use was made by the planning institution by the commencement date shall be subject to accessibility adjustments in accordance with the Existing Educational Institution Regulations and also the provisions of sections 19ag3 and 19ah of the Equality Law.

7th Av 5778 (19 July 2018) Aryeh Makhlouf Deri

Minister of the Interior

Page 2 of 2